Management of pulse oximeter probe–induced finger injuries in children: report of two consecutive cases and review of the literature

      Abstract

      Pulse oximetry is a standard noninvasive procedure for monitoring arterial oxygen saturation. Finger injuries related to pulse oximeter use have been reported as chemical or thermal burns, sun-tanning, pressure erosion, sensory loss, and gangrene. The mechanisms of these complications have not been definitively explained; but pressure ischemia, prolonged use, overheating of the probe, inappropriate use of the probe, and short circuiting are considered to be the main factors. We describe 2 cases of pulse oximeter probe–induced finger injuries, propose the possible mechanisms and factors related to the injury, and discuss the management.

      Key words

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Journal of Pediatric Surgery
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Sobel D.B.
        Burning of a neonate due to a pulse oximeter: arterial saturation monitoring.
        Pediatrics. 1992; 89: 154-155
        • Baruchin A.M.
        • Nahlieli O.
        • Neder A.
        • et al.
        Finger injury from a pulse oximeter sensor during orthognathic surgery.
        Ann Medit Burns Club. 1993; 6: 41-43
        • Ghai B.
        • Naik A.
        • Rupal S.
        • et al.
        Toe gangrene in an infant subsequent to use of pulse oximeter for short duration.
        Anesth Analg. 2005; 100: 602
        • Jung S.N.
        • Hwang D.Y.
        • Kim J.
        • et al.
        Pulse oximeter probe–induced electrical burn.
        Burns. 2009; 35: 751-753
        • Jeon D.G.
        • Kim S.K.
        • Lee G.W.
        • et al.
        Skin burn associated with pulse oximeter: a case report.
        Korean J Anesthesiol. 2007; 52 (Korean): 228-230
        http://dx.doi.org/10.4097/kjae.2007.52.2.228
        • Pettersen B.
        • Konsgaard U.
        • Aune H.
        Skin injury in an infant with pulse oximetry.
        Br J Anaesth. 1992; 69: 204-205
        • Miyasaka K.
        • Ohata J.
        Burn, erosion, and “sun” tan with the use of pulse oximeter in infants.
        Anesthesiology. 1987; 67: 1008-1009
        • Punj J.
        • Jaryal A.
        • Mahalingam S.
        • et al.
        Toe gangrene in an infant subsequent to application of adult-type pulse oximeter probe for 10 min.
        J Anesth. 2010; 24: 630-632
        • Wille J.
        • Braams R.
        • Van Haren W.
        • et al.
        Pulse oximeter–induced digital injury: frequency rate and possible causative factors.
        Crit Care Med. 2000; 28: 3555-3557
        • Choi M.
        • Armstrong M.B.
        • Panthaki Z.J.
        Pediatric hand burns: thermal, electrical, chemical.
        J Craniofac Surg. 2009; 20: 1045-1048